Thermo Tech Systems Limited

Thermic Fluid System
Product Description

Thermic Fluid Heater -Liquid/Gas Fluid Heater :
“Thermotech” : Thermic Fluid Heater’s are available in Horizontal & Vertical Models where in thermic fluid can be heated up to normal 340 oC at near atmospheric pressure with efficiency as high as 92% on GCV of Oil and Gas fuel.  

Thermic Fluid Heater Capacity = 1 Lac Kcal/hr to 120 Lac Kcal/hr

Maximum Temperature = 370 Deg. C

Application:

Chemical, Textile, Technical Textile, MDF and Particle Board, Plywood and Laminates, Oil & Gas, Packaging, Rubber, Pharmaceuticals, Food Processing, Metal, etc...

Fuel to Handle : Furnace Oil, LDO, Diesel, N. Gas, LPG, Hydrogen, etc..

Quality Assurance : ISO 9001 : 2008 since more than 7 years.
 
Thermic Heater - Gas Oil / Fired Burner:
 
“THERMOTECH” : THERMIC FLUID HEATER’S are available in HORIZONTAL & VERTICAL MODELS where in thermic fluid can be heated up to normal 340 oC at near atmospheric pressure with efficiency as high as 92% on GCV of Oil and Gas fuel.
 
The Main Heat Exchanger is designed with an integrated combustion chamber made out of High Heat Resistant Steel Tubes : BS 3059 P-1 or Seamless Pipes : SA106 Gr.B S40 of adequate size, explicitly designed with twin concentric multi start helical coil. The Coil is inserted into M.S. Shell with structures supports to place complete assembly leveled.
 
The system is 3 pass on flue gas side, which ensures optimum heat transfer with counter current flow principle. The combustion chamber is designed to maintain safe distance between coil tube surface and burner flame, which ensures optimum heat transfer, long thermic fluid life due to lesser film temperature & safety of helical coil tube, which ultimately safeguards the complete heat exchanger.
 
HORIZONTAL UNIT WITH EXTERNAL AIR PRE HEATER
 
This new “HT” series of Thermic Fluid Heater – Horizontal model is improved version, which have demonstrated their good design & to which new Technologies & Materials are added to improve efficiency up to 93%, energy saving, simplify the maintenance, low smoke emission & able to integrate with PLC & SCADA system with ease.
 
The Stack Heat from Exhaust flue gases of Main Heat Exchanger are recovered by means of Combustion Air Pre Heater (CAPH) & fresh combustion air is preheated before going to burner, which improves combustion efficiency, reduces stack temperature, reduce fuel consumption & save environment.
 
THE  COMBUSTION FUELS :
 
“THERMOTECH” : Thermic Fluid Heaters are designed for all commercial & special fuels available in market for combustion.
Fuels like : Kerosene / Diesel / Light Diesel Oil (LDO-LFO) / Furnace Oil (HFO) / Natural Gas / LPG / Pipeline N. Gas, etc. are combustible with same efficiency, which is thankful to our combustion experts who designs combustion parameters & Air to fuel ratio for best output.
 
Thermic Fluid Heater -Solid Fluid Heaters:
 
Salient Features of This Model

Furnace is designed for multi fuel options, with major thrust on proper selection of combustion grate, furnace height, combustion volume, fuel feeding systems. To ensure efficient combustion & lesser heat loss. 

Coils are designed with optimum flow consideration to gain maximum heat from flue gases. Coils are tested at 3 stages before final dispatch as a part of Thermotech’s stringent quality control. 

ID Fan, FD Fan & booster fan (in any) are selected as per fuel’s perfect air-fuel ratio requirement, which ensures optimum air quantity for combustion & thus saves power consumption. 

Expansion Tank capacity is specifically selected after consulting total holdup of Thermic Oil. Deaeration Tank is specially designed considering flow & temperature requirement.

Thermotech offers complete solution of Thermic Fluid heating system along with Pipeline, Pollution control equipments, fuel handling, etc on Turnkey basis.
 
Auto Controls & Safety
1.Thermic Fluid Temperature control 
Digital temperature indicator-cum-controller cut of ID/FD fan of preset temperature and restart of preset temperature and restart of preset differential temperature to maintain system temperature.

2.Stack Temperature Control 
A blind temperature controller cut of ID/FD fan and sound alarm if stack temperature exceeds to preset temperature.

3.Low/NO Flow of Thermic Fluid 
Differential pressure switch connected across intel and outlet headers signals low flow alarm in case of low fluid pressure of Thermic fluid in coils.

4.Low Level of Thermic Fluid 
The visual level indicator and float actuated lever switch fitted in expansion tank signals alarm in case of low level thermic fluid in the system.

5.Thermic Fluid Pump Motor Trip 
In case of thermic fluid pump motor trip, electrical interlocks, cut off ID/FD fan.

6.Power Failure 
Diesel engine drive keeps thermic fluid moving in the system to prevent its degradation and overflow.

7.Excess Furnace Bed Temperature 
Digital temperature indicator-cum-controller senses furnace bed temperature and cut off ID/FD fan above set value(for FBC unit).
Benefites :
  • Multi-Fuel Option
  • Low Power Consumption
  • Energy Optimization
  • Low Maintenance
 

 

Company Profile:

Today, the Company by its continuous quality encroachment had earned an ISO 9001:2008, which ensures quality management services & hence an improved product quality. Thermotech enjoys a wide spread satisfied client base of around 1500, also that the company’s products are being exported to neighboring countries. All the product are very well received and commands high rate of preference in the market.
 
The Company is promoted and backed up by a team of highly qualified and experienced technocrats and professionals fully devoted to their respective field- Production, Marketing, Administration etc., Besides, it is heavily banking on its trump card, a prompt and efficient after sales service. All these put to gather have led us to what we are today.
 
Our Vision :

To be leaders in providing solutions for PROCESS HEATING, through consistent quality products & complete customer satisfaction.

Place Your Inquiry Here


Please enter your name, email and message to reply to ad author.

*All fields are required.
Name: Company Name:
Email: ContactNo:
Subject :    
Your Message: Note: This form can only be used for reply to ad author.
Sending unsolicited email advertisements is strictly prohibited!
Length: Characters Left