Product Specifications
Horizontal Laminar Flow Workstation:
Available Sizes
HORIZONTAL LAMINAR FLOW WORKSTATION DIMENSIONS |
PRODUCT # |
EXTERNAL DIMENSIONS |
INTERNAL DIMENSIONS |
WIDTH |
HEIGHT |
DEPTH |
WIDTH |
HEIGHT |
DEPTH |
AC4000HLF |
48″ |
41″ |
30″ |
41″ |
27″ |
19″ |
AC5000HLF |
60″ |
37″ |
30″ |
52″ |
27″ |
19″ |
AC6000HLF |
72″ |
37″ |
30″ |
65″ |
27″ |
19″ |
AC8000HLF |
96″ |
37″ |
30″ |
89″ |
27″ |
19″ |
Product Description
Laminar Flow Hoods:
AirClean® Systems manufactures a wide range of ductless laminar flow hoods, workstations and clean benches for creating a particle-free Class 100 (ISO 5) environment. These workstations are available in numerous sizes and styles to meet a variety of applications.
An AC600-series vertical laminar flow cabinet is smaller in size, providing a more mobile workstation. For certain applications, our horizontal clean bench models (ranging from 52″ to 102″ inches in width) may be a better choice. A custom laminar flow hood can be designed if your application demands it.
Vertical Laminar Flow Workstation:
AirClean® Systems AC600 Series vertical laminar flow workstations are ideal for applications that are not hazardous to the operator but require a clean work area. The compact, light weight design allows for multiple "clean zones" within a laboratory.
The vertical laminar flow workstation provides clean Class 100 laminar flow air for process protection by using a two stage filtration process. Room air is first cleaned with an electrostatically charged prefilter and then further cleaned with a HEPA filter. AirClean Systems vertical laminar flow workstations have been independently certified to meet or exceed applicable clean bench standards.
Features
- UVTect™ microprocessor controller
- Class 100 (ISO 5) vertical laminar flow
- 360-degree visibility
- Integral polypropylene base for easy cleaning
- All thermoplastic construction
- Built-in fluorescent light
- HEPA filter monitor automatically indicates when filter change is required
- Available in 24″, 32″ and 48″ widths
- Available in 110 V or 220 V versions
Options
- Shortwave UV light
- Custom sturdy cart allows unit to be made portable
- All polypropylene - metal free construction available
- ULPA filter
- Sliphatch access port
Horizontal Laminar Flow Workstation:
Constructed from all white seamless polypropylene, AirClean® Systems horizontal laminar air clean benches are the ideal solution for Class 100 (ISO 5) applications. Standard on all horizontal laminar airflow workbenches, the UVTect™ controller constantly monitors filter conditions, alerting the operator of insufficient airflow.
A typical application for the AirClean® Systems laminar airflow workbench is inspection of parts or the assembly of optics that require a clean, particulate free environment. Our laminar flow clean bench is constructed from polypropylene and features rear wall filtration, making it perfect for this and other critical applications and manipulations.
Features
- UVTect™ microprocessor controller
- All polypropylene construction - NO MORE RUST!
- Seamless, smooth construction minimizes air turbulence
- Built-in fluorescent lighting
- All-white surfaces are easy to clean
- Meets ISO 5 and FS209E Class 100 clean bench standards
- 110V or 220V versions
AirClean® Systems horizontal laminar flow bench provides a HEPA filtered airflow across the work area, and a particulate-free work surface. While an AirClean Systems tissue culture hood provides excellent process protection, it does not provide any personal protection from the application. AirClean Systems tissue culture hoods are not designed to be used for biological samples.
All AirClean® Systems horizontal laminar flow clean benches receive rigorous QC/QA testing for cabinet and filtration integrity.
Typical Applications
In addition to optics preparation as mentioned above, a horizontal clean bench from AirClean Systems makes an excellent tissue culture hood. Other typical applications of clean benches are:
- IV admixture preparation
- Drug Compounding
- Plant Cell Culture
- Tissue Culture (non-biological)
- Media Preparation
- Pharmaceutical procedures
- Electronic assembly
Options
- Custom sturdy carts
- Cup sink and vacuum fittings
- Polypropylene base cabinet
- Ultraviolet light source
Free-Standing Clean Room Enclosures
AirClean® Systems free-standing, polypropylene vertical laminar flow clean room hoods protect the application from airborne particulate contamination. Designed to bathe the process in HEPA clean air, a polypropylene free-standing hood is ideal for enclosing pipettors, equipment that requires a particle-free environment or creating clean rooms within a large manufacturing facility or warehouse for product sampling.
Free-standing enclosures provide a variety of options, from small drum sampling stations to enclosing complete assembly applications. Contact one of our qualified technical sales specialists to determine which clean room hood best fits your needs.
Features
- UVTect™ microprocessor controller
- Solid polypropylene construction for maintaining a clean environment
- Fluorescent light
- Easy access for filter change
- Standard with HEPA filter but may be fitted with ULPA filters
Options
- Multiple sash or door configurations available
- Access ports and doors
- Front or rear filter access
- Short wave ultraviolet light
NOTE: Free-standing clean room enclosures are considered custom enclosures. This product will not protect the operator from biological hazards.
AirClean® Systems manufactures a complete range of ductless fume hoods and laminar flow hoods designed to protect the operator, the process, or both from toxic vapors, fumes, gases, and particles.
AirClean® Systems ductless fume hoods, workstations and enclosures are designed to protect the operator, process or both from toxic vapors, fumes, gases and particulate. For process protection, an AirClean® Systems laminar flow hood provides a clean work area for amplification or manipulation. At the heart of all AirClean®Systems fume hoods, workstations and enclosures is a revolutionary gas phase bonded carbon filter. This unique filter, found only in AirClean® Systems safety products, eliminates filter dusting and dead zones associated with traditional granular carbon filters. Each unit uses a microprocessor-based automatic safety controller, keeping a constant check on airflow and filter quality, and alerting the operator in the event of filter saturation.
For questions about a specific product or to determine which AirClean® Systems product best fits your needs, contact one of our qualified technical sales specialists at 800-849-0472 (within the US) or +1 919-255-3220.
In addition to a full range of fume hoods, AirClean® Systems manufactures Forensic Containment Products andMedical Containment Products.