Delta Cooling Towers, Inc

Cooling Tower
Product Specifications

 Cooling Towers:

TM Series Induced Draft Towers:

Premier Induced Draft Tower:

Paragon Induced Draft Towers:

Pioneer Forced Draft Towers:

Product Description

Cooling Towers:

 
TM Series Induced Draft Towers:
 
Delta’s TM Series™ induced draft, counter flow design are available in single unit capacities from 250 to 2,000 cooling tons.
Manufactured since 2001, the TM Series™ has been very well received in both commercial and industrial applications.
The modular design allows isolation of cells for operational flexibility.
 
Standard Features:
  • Seamless Double Wall Engineered Plastic (HDPE) Shell
  • Corrosion Proof Construction
  • Direct Drive Fan System
  • Totally Enclosed VFD Rated Motors
  • Factory Assembled for Simple Installation
  • 20 Year Shell Warranty
  • PVC Water Distribution System with Non-clog Large Orifice Removable Nozzles
  • High Efficiency PVC Fill
  • Made in the USA
Premier Induced Draft Tower:
 
Delta’s Premier™ induced draft, counter flow, low profile design is available in single module capacities from 250 to 500 cooling tons.
These towers use the same unitary seamless engineered plastic construction that Delta has been manufacturing since 1997, and have been very well received in both commercial and industrial applications.
Premier’s cost less to install and operate!  The light weight construction reduces rigging and structural roof support requirements. While maintenance and water treatment chemical costs are significantly lowered.
 
Standard Features:
  • Seamless Engineered Plastic (HDPE) Shell
  • Corrosion Proof Construction
  • Coated Steel Mounting Platform
  • Direct Drive Fan System
  • Totally Enclosed VFD Rated Motors
  • Completely Factory Assembled
  • 20 Year Shell Warranty
  • PVC Water Distribution System with Non-clog Large Orifice Removable Nozzles
  • High Efficiency PVC Fill
  • Made in the USA
Paragon Induced Draft Towers:
 
Delta’s Paragon® Induced Draft, counter flow design is available in single module capacities from 55 to 250 cooling tons.
Manufactured since 1981, the Paragon® tower has been very well received in both commercial and industrial applications.
Paragon’s unique design provides unlimited flexibility of modular operation, future upgrade capability and location convenience.  Unitary molded of  HDPE, these towers are light weight, strong and long lasting, and backed by a 15-year warranty!
 
Standard Features:
  • Seamless Engineered Plastic (HDPE) Shell
  • Corrosion Proof Construction
  • Direct Drive Fan System
  • Totally Enclosed VFD Rated Motors
  • Factory Assembled for Simple Installation
  • 20 Year Shell Warranty
  • Low Pressure Drop Self Propelled PVC Water Distribution System
  • High Efficiency PVC Fill
  • Made in the USA
Pioneer Forced Draft Towers:
 
Delta’s Pioneer® forced draft, counter flow design is available in single module capacities from 10 to 100 cooling tons.
Manufactured since 1971, this unitary seamless engineered plastic design has been manufactured since 1971 and have been very well received in both commercial and industrial applications.
 
Standard Features:
  • Seamless Engineered Plastic (HDPE) Shell
  • Corrosion Proof Construction
  • Forward Curved Centrifugal Blower with Totally Enclosed Motor.
  • Factory Assembled for Simple Installation
  • 20 Year Shell Warranty
  • PVC Water Distribution System with Non-clog Large Orifice Removable Nozzles
  • High Efficiency PVC Fill
  • Made in the USA

Company History:


Delta Cooling Towers, Inc. was founded to manufacture and market the initial concept of a maintenance free seamless one-piece non-corrosive Polyethylene cooling towers, and sold its first unit in June 1971.
 
Delta’s PIONEER® forced draft cooling tower line is factory assembled in single modules from 10 through 100 tons of cooling capacity.
 
Delta’s PARAGON® induced draft cooling towers are factory assembled in single modules, from 100 to 250 tons in single modules.
 
Delta’s PREMIER™ induced draft cooling towers are offered in 6 single-cell models ranging from 250-500 cooling tons, and features a low profile design.   They are designed for ease of installation to span existing cooling tower structural supports.  The Premier™ towers come standard pre-mounted on a steel platform.
 
Delta’s TM Series™ cooling towers are supplied from 250 up to 2000-ton capacity in multi-module systems, and are CTI certified.  They are a double wall polyethylene construction designed in two sections for shipment purposes.  The tower section includes the wet decking, the hot water distribution system, the mist eliminator and the motor/fan assemblies with the velocity recovery fan stacks.   The other section is the cold-water basin.
 
In 1981 Delta entered the air stripper market and currently markets a standard line of VANGUARD® packed column air strippers from 1′ through 5′ diameter.  Larger custom designed systems can be provided up to 15′ diameter.

Delta prides itself in its ability to provide the technical expertise necessary to meet the requirements of any application with respect to stripper design, materials of construction, type of packing and total system capability.  Our capabilities are listed in our general literature, which also shows installation photographs of some of Delta’s air stripper applications. 

Place Your Inquiry Here


Please enter your name, email and message to reply to ad author.

*All fields are required.
Name: Company Name:
Email: ContactNo:
Subject :    
Your Message: Note: This form can only be used for reply to ad author.
Sending unsolicited email advertisements is strictly prohibited!
Length: Characters Left