Gordhandas Desai Pvt. Ltd

Fume Hood
Product Specifications

 Fume Hoods:

Description:

 
Model No. & Overall Normal Size in mm of Fume Hood (without Fume Hood base ) BFH 1200 (1200 x 950 x 1450) / BFH 1500 (1500 x 1050 x 1450 ) / BFH 1800 (1800 x 1050 x 1450) / BFH 2100 (1800 x 1050 x 1450) / BFH 2400 (1800 x 1050 x 1450) Tailor made / 
Customised as per
customer requirement
Model No. & inside Fume hood working dimension ( in mm) BFH 1200 (900x650x1200) / BFH 1500 (1200 x 750 x 1200) / BFH 1800 (1500 x 750 x 1200) / BFH 2100 (1800 x 750 x 1200) / BFH 2400 (2100 x 750 x 1200)
Model No. & Bench Hood Base length in mm x Depth in mm x Height in mm BFH 1200 (1200 x 840 x 800) / BFH 1500 (1500 x 940 x 800) / BFH 1800 (1800 x 940 x 800) / BFH 2100 (2100 x 940 x 800) / BFH 2400 (2400 x 940 x 800)
Length in mm x depth-Sash to Baffle in mm x height in mm BFH 1200 (1050 x 600 x 1200) / BFH 1500 (1200 x 750 x 1200/1350) / BFH 1800 (1500 x 750 x 1200/1350) Tailor made / 
Customised as per
customer requirement
Length in mm x depth-Sash to Lattice in mm x height in mm BFH 1200 (1050 x 500 x 1200) / BFH 1500 (1200 x 650 x 1200/1350) / BFH 1800 (1500 x 650 x 1200/1350)
Construction material External GI epoxy powder coated / SS 316 / SS 304, Internal Liners as required

 

Exhaust systems Constant Air Volume / Variable Air Volume / Auxiliary Air Supply
Sash configuration Standard Vertical Sliding / Combination of Vertical Rising and Horizontal Sliding / Auto Sash Vertical Rising / Horizontal Sliding Door for Walk-in Fume Hood
Liner option Fibre Glass Reinforced Plastic (FRP) / Stainless Steel (for Radioactive and Perchloric Acid use) / Polypropylene (PP) / Phenolic Resin
Work surface Dished Ceramic / Dished Jet Black Granite / Imported Black Epoxy Top / Raised Edge / Dished SS 316 / 304 as required
Drip Cup / Sink Flanged PP Black Drip Cup with outlet coupling of sizes - Round - 100 mm dia / 150 mm dia / 200 mm dia or Oval - 220 mm x 100 mm x 170 mm - Deep / Customised size / SS 316 Rectangular / Round / Ceramic
Lattice / Scaffolding GI - PU Coated / SS 316 / Aluminum Alloy Rods
Electrical Fittings North - West make 6/16 A Socket & 16 A MCB Switch - Qty. as per requirements / Industrial BCH Sockets & Switch / Optional - Special
Valves / Faucets / Services Remote operated Front Panel mounted - Valves - Water, Chilled Water, D.M. Water, Nitrogen, Gas, Vacuum, Compressed Air / Any other service with Spoutes / Nozzles of 90 degree / 45 degree fitted on sides of Fume Hood
Temperature Indicator Optional Range - 50 degree to + 150 degree Centigrade with RTD Sensor PT-100
Face Velocity Meter Optional - TEL AFA 1000/1 / Equivalent Make and Model
Airflow Indicator Optional - TEL AFA 500/1 or AFA2S / Equivalent Make and Model
BFV Inbuilt - PP / GI / SS for initial manual set-up , Optional - Motorised Damper for VAV Controls
Blower Imported PP Casing & Impeller / PP-FRP Casing & Impeller / SS Casing & Impeller / Tailor made / Customised as per customer requirement
Colour  Ivory /  Orange /  Cool Blue /  Red /  Green /  Blue / 
  Munshell Grey
Product Description

Fume Hoods:

GD is a pioneer in the field of Fume Hoods & Fume Extraction Systems. Constant innovation, stringent quality control and improvements in manufacturing processes ensure that Labexcel Fume Hoods are the best and undoubtedly the leader in the segment.

Besides being available in a wide range of models, Labexcel Hoods are designed to offer the complete solution to laboratory ventilation concerns. Integrated components including fume hoods, blowers, ducts, electrical services, plumbing options and base cabinets combine to provide a safe, efficient fume hood system for your laboratory.

Principal Features of Labexcel Fume Hoods

 

Removable Back Baffle

Easily accessible controls for service and electrical works

Fully illuminated workspace
Wide choice of sash arrangements
Wide choice of chemically resistant linings
Digital Face Velocity Meter with Alarm / Low Exhaust Indicator – optional feature to work with safe face velocity
Efficient louver and bypasses
Side panels can be opened for maintenance
Aerodynamic design
In-house fume hood performance testing facility as per ASHRAE 110-1995 guidelines
Customized fume hoods offered for various applications like handling radioactive material, low maintenance, highly efficient, low noise, chemical resistant poly propylene blower
 
To make sure that the Fume Hoods we provide are the best among the available, especially in the context of your safety, they are tested under rigorous conditions.

Fume Hood Testing:

GD is the first Indian Laboratory Furniture Manufacturer to have established a state-of-the-art testing laboratory at the factory to evaluate the fume hoods performance as per ASHRAE- 110 (American Society of Heating, Refrigerating and Air - Conditioning Engineers) test as per the AM guidelines. It is a relative and quantitative determination of the efficiency of a fume hood to capture contaminants under a set of strict conditions.
The Test Laboratory is equipped with proper room pressurization system which generates air to be exhausted from the Fume Hoods being tested. The airflow is designed to provide turbulence free air entry at the front of the Hood. The test room has tight room envelope and precision electronic controls to maintain proper room pressurization.
All "Labexcel" Fume Hoods are type tested for their safety performance as per tests below:
Flow Visualisation Test
For low challenge, a small quantity of smoke is used for visual study of smoke flow pattern. For high challenge flow visualization, copious amounts of smoke is generated and released into the Fume Hoods.
Face Velocity Test
The sash is divided into grids and face velocity is measured at each grid point to analyze minimum, maximum and mean face velocity.
Gas Containment Test
This is a quantitative test where in a known quantity of gas is released within the Fume Hood and its leakage is measured at a stimulated breathing zone with an ultra precision Leak Meter and analysed.
Sash Movement Effect Test
The leakage of tracer gas is measured at rapid sash movement at the stimulated breathing zone.

VAV Response Test:

This is done when VAV controls are used for Fume Hood. The time required to regain the velocity at full designed velocity is measured.

We know that different laboratories have different needs, so we have built a wide range of Fume Hoods and other safety equipment to help you choose the right fit. And if you have a typical need, we will make one which is tailor 
made for you.

Select from a range of Labexcel 
Fume Hoods Models like Bench Fume Hoods, Walk-In Fume Hoods, Low-Bench Fume Hoods, Special Purpose Fume Hoods, Customised Fume Hoods of assorted sizes from widths of 750 mm up to 2400 mm and with Liners like FRP, Polypropylene and with work surfaces ranging from Fibre Glass, Stainless Steel, Plastic Sheets, Epoxy Coated Steel, Ceramic Tiles, Granite and Imported Solid Epoxy Tops. Different Fume Extraction Systems are also provided for Fume Hoods like AAV, CAV and VAV (Conventional, By-Pass Air, Restricted By-Pass and Auxiliary Air).

About Us:


GD began manufacturingLaboratory Furniture and Fume Hoods at a factory in Vadodara in 1979. A modest beginning, powered by a futuristic vision, constant innovations, research-driven endeavours, steadfast commitment to quality and customer-focused service principles made GD emerge as a pioneer in this field.

Experience at work
An experience distilled over a period of more than 3 decades in manufacturing, makes GD an expert in the field of Laboratory Infrastructure resulting in the best products in the market. We proudly present our `Labexcel` range which is short for `Laboratory Excellence`, the brand name under which GD offers "Total Laboratory Engineering Solutions". This wealth of experience makes Labexcel, the most favoured name among the country`s scientific community.
Quality - a norm
Quality is the most common ingredient in all our products and services. Continuous improvement in processes and systems lead to a product, compliant to the quality standards our customers expect from us. Our quality consistently conforms to industry standards. We were one of the first few companies to get the ISO certification, forLaboratory Furniture Systems and Fume Hoods. Besides ISO 9001:2008 certification, we also have IS0 14001:2004 and OHSAS 18001: 2007 certifications.
Customised solutions
Our expertise over the years has helped us improve our understanding of the needs of different kind of laboratories through a broad variety of our customers, which include pharmaceutical, food, chemicals, plastic & polymers, environment, education, petroleum, healthcare among other industries. The wide range of our manufacturing capabilities permits us to produce tailor-made items of all dimensions and specifications to offer complete need-based solutions to our customers.
Cutting edge technology at the core
Extended over an area of 50,000 sq. ft. our manufacturing facility near Vadodara is equipped with state-of-the-art plant and machinery including automatic powder-coating facility. A comprehensive set-up for design, production, marketing and after-sales services ensure that we employ cutting-edge technology leading to 100% satisfaction of the customer.

Place Your Inquiry Here


Please enter your name, email and message to reply to ad author.

*All fields are required.
Name: Company Name:
Email: ContactNo:
Subject :    
Your Message: Note: This form can only be used for reply to ad author.
Sending unsolicited email advertisements is strictly prohibited!
Length: Characters Left