Air Handling Unit - Comparison of Technical Data:

 
AIR QTY.: 13600 CMH ( 8000 CFM) 13600 CMH ( 8000 CFM)
ST. PR. 1250 Pa ( 125mm WC ) 1250 Pa ( 125mm WC )
TYPE OF FAN : PLUG FAN DIDW BACKWARD CURVED FAN
FAN DIA. : 710mm 500mm
FAN MAKE : PUNKER ( Germany ) AN AMCA CERTIFIED MAKE
FAN SHAFT POWER : 6.21 KW 7.07 KW
FAN EFFICIENCY : 75.0% 70.7%
TYPE OF MOTOR : TEFC. SQ. CAGE TEFC. SQ. CAGE
MOTOR SIZE : 7.5 KW ( 10.0 HP ) 9.30 KW (12.5 HP)
COIL FACE AREA 1.49 SQ.MT 1.49 SQ.MT
COIL SIZE 1143 FH X 1300 FL- 6RD 1143 FH X 1300 FL- 6RD
UNIT DIMENSIONS : L 3350 XH 1400 X W1650 L 4100 XH 1400 XW 1650
WEIGHT : 975 kgs 1250 kgs
Product Description

Air Handling Unit / Air Handlers:

Features of Air Handlers with German Technology Direct Driven PLUG FANS:
  • Low Power Consumption
  • Compact In Design
  • Silent in Operation
  • Lesser Weight
  • No Belt Drive Package, means ...
    • maintenance free
    • more reliability
    • No carbon generation within the unit
  • Choice of Multiple Air Outlets
    • air distribution plenum can be eliminated
  • Fan Motor can be kept out of air stream
    • reduced heat load, no fire hazards
  • Most ideal for
    • Operation Theatres, Pharma Units, and other Clean room applications
    • Electronic, Software and IT Industry
    • Multiplex Cinemas and any public area having variable load pattern
    • Switch Rooms
Air Handling Unit - How Plug Fans were Invented
For the modernization of telecommunication distributing centre in Germany, a large number of Air Handling Units and Air Handlers was required. The modernization was agreed on the condition of a substantial reduction of yearly energy costs. The Original belt driven fans had rather high energy demand causing high energy costs. There was hardly and belt driven system which could satisfy the requirement of the user.
 
The use of direct driven fans without housing ( generally known as Plug fans) reduced the energy demand to a large extent. In addition to this, annual servicing cost also reduced considerably as Plug Fans are maintenance free. The manufacturers and users of AHUs recognized the advantages of Plug fans and modified their equipment accordingly.
 
Punker GmbH & Co., Germany played a major role in introducing the use of direct driven fans for AHU applications. In Europe, the Plug fans are very extensively used for Air Handling Units as well as for Air Handlers.
 
CITIZEN is proud to introduce the PLUG fan technology in India, where energy conservation and cleaner environment is of prime importance. CITIZEN has a tie up with PUNKER GmbH & Co., to provide total solutions for any kind of fan requirement. CITIZEN has successfully executed many installations of AHUs with PLUG fans after its FIRST installation in 1997 at Pune. CITIZEN is grateful to Zydus CadilaCipla Limited and Dikshit Consultants who encouraged CITIZEN by accepting Plug Fan technology for clean room and sterile area applications for the first time in India.

 

About Us:

 
The founder Director and CEO of Citizen Group Mr. Kamalesh Mehta established a Small Scale industry in 1986 for manufacturing of Fan Coil Units and Air-Conditioning Equipment fordomestic application. Mr Mehta acquired the work experience for 6 years in the field of marketing, designing and installation of air-conditioning equipment prior to starting his own industry.
 
Within a short span, in 1990 the group established another unit for the manufacturing of Air Handling Units with larger manufacturing setup. In 1992, one more factory was established for the manufacturing of Cooling and Heating Coils.
 
Considering continuous rise in demand and addition in product range, the group felt the necessity for larger manufacturing facility. In 1997, the group established a larger factory of about 4,000 sq.mt in approx. 10,000 sq.mt. land area forming a closely held public limited company. To minimize the product cost and to have better control over quality, company installed all necessary manufacturing facility in-house. Also to have better command over production activities, the operations were centralized merging two smaller units with the new one.
 
In 1999 Citizen Group ventured into another product line, close to its original business ofHVAC equipment. The group started the manufacturing of equipment related to Lab environment acquiring a property of approx 3,500 sq.mt. built up area. All the products manufactured in the new line are unique in technology and highly appreciated by users.
 
Today, the group has full-fledged large manufacturing facilities at three locations and fully equipped administration and marketing office at the most prime location of city. Citizen group is providing employment to more than 270 people with fast growing turnover.

Sky is the limit......both the major factories of the group have now initiated the actions for 100% expansion. New facilities are scheduled to be in operation by September 2005. Citizen group is enjoying good reputation all over the country. 

Place Your Inquiry Here


Please enter your name, email and message to reply to ad author.

*All fields are required.
Name: Company Name:
Email: ContactNo:
Subject :    
Your Message: Note: This form can only be used for reply to ad author.
Sending unsolicited email advertisements is strictly prohibited!
Length: Characters Left