Hi-Tech Coatings

HDPE Tank
Product Specifications

 HDPE / PP MOULDED STORAGE TANKS:

SPECIFICATION OF HDPE / PP CO - POLYMER MOUDED TANKS:


(A) Cylindrical - Vertical

Capacity Dia Height Manhole Wall Thk.
300 700 825 280
3.0
400 760 850 280 3.5
500 850 1000 450 4.0
750 1000 1100 450 4.5
1000 1070 1250 450 4.5
1500 1180
1360
450
4.5
2000 1320 1525 450 5.5
3000 1500 1750 450 8.0
5000 1850 1950 450 10.5

 

 

(B) Rectangular - Horizantall:


  Length Width Height Manhole Wall Thk.
150 660 660 410 280
2.75
225 865 700 380 280 2.75
275 1015 685 410 280 2.75
300 1285 625 420 280 2.75
325 1155 900 355 280 2.75
350 1285
625
495 280
2.75
400 1525 915 305 280 2.75
425 1195 890 420 280 2.75
470 1375 980 370 280 2.75
500 1575 1145 305 280 2.75
525 1535 890 410 280 2.75
550 1525 765 510 280 2.75
600 1475 1065 410 280 3.00
700 1475 1065 470 280 3.00
750 1675 915 510 280 3.50
825 1535 915 610 280 3.50
900 1220 1220 610 280 4.00
1000 1780 990 610 280 4.00

 

Product Description

HDPE / PP MOULDED STORAGE TANKS 

About Us:

 
We would Like to Introduce ourselves as leading HALAR & PTFE Coating & Lining unit for the Equipments and Parts, which are used in API, BULK Drug, pharmaceutical, Food, Fine Chemical, Inorganic Chemical, Petrochemical, Ore and Surface treatment.
HALAR / PTFE / PFA Coating is recommended where Highly Corrosive and Abrasive product are processed . This Corrosion resistance coating is carried out on MS/SS material of processing equipment, like Centrifuge Machine, Rotary Vacuum Cone Dryers, Agitated Nutsche Filters, Heat Exchanger, Agitators, Receivers, Tanks, vessels Pipes, Thermo wells Fittings, Strainers, Valves and Spares for Glass Lined Equipment etc. We manufacture Chemical Plant Equipment with Coatings / Lining also.

PROCESS / PLANT DETAILS :-
  • Coating Thickness           : 30 micron to 1.5 mm
  • Lining Thickness              : 1 mm to 5 mm
  • Furnace                           : 3 No`s
  • Furnace Size (Max)          : 9 ft X 9 ft X 7 ft
  • Testing Equipments         : Thickness Tester , D.C. Spark Tester , Hydro Test Pump etc. as per                                           international standards
We also offer Anti static - Electro dissipative as - HALAR, as - ETFE, as - PFA coating. This is Safe for process, plant & people .This Coating is Food Compatible.
 
Some Advantages of HALAR / PTFE / ETFE / FEP / PFA / Coating / Lining :
  • A Universal Chemical resistance
  • Free from Maintenance easy to clean
  • Safety while handling HAZARDOUS material.
  • Higher Performance and lower cost than other exotic material like Hastelloy, titanium etc.
Equipments, Piping & Valves.

Due to outstanding corrosion resistance and relatively low cost of fluoropolymer it has established as an important alternative to exotic alloys 8c brittle glass lining as a
construction material for chemical and pharmaceutical equipment.

While glass lined reactors are common enough, columns. Tanks, receivers, filters, condensers, pipes valves In fluoropolymer coating & lining are manufactured & supplied by us, since more than 19 years.

Considering safety of the plant persons machinery, we have introduced,
Conductive (Anti - Static ) HALAR as well as PFA Coating Whose electrical resistance 
is in the range of 10e6 - 7 ohm / square, which dissipates static electricity charge in a fraction
of a second. This reduces explosion hazard where by saving in loss of life, equipment &
production.

We Construct Tanks & receivers in Seamless Construction in Metal MS/SS coated with PVDF, HALAR, PFA etc., up to 3000 ltr. Capacity in vertical or Horizontal mounting & in solid HDPE & PP up to 5000 ltrs. Capacity.

We also manufacture Chemical Storage Tanks up to 50000 ltrs. Capacity, fabricated in Spiral WoundHDPE & PP Construction.
 

Now We have introduced PFA coated shell & Tube Heat Exchangers as well as U-Tube Heat exchangers. They are available in shell diameters from 150 NB to 600 mm NB, and Heat transfer area of 1.0 m2 to 12.0 m2 heat transfer coefficient up to 400 kal / m2C. They can be in use from - 100° to 200° C & from full vacuum to 10 kg / cm2 pressure. The compactness & low cost of the new PFA coated exchanger makes them ideal for corrosive media when metallic materials are too expensive. They can be used as condensers, evaporators or liquid - liquid heat exchangers & mounted vertically or horizontally. Without its shell, U Tube bundle can also be used in a reactor to increase heat transfer area. 

Place Your Inquiry Here


Please enter your name, email and message to reply to ad author.

*All fields are required.
Name: Company Name:
Email: ContactNo:
Subject :    
Your Message: Note: This form can only be used for reply to ad author.
Sending unsolicited email advertisements is strictly prohibited!